EVERTECT

Access Control System

Intelligent Lock

It is a dual-purpose intelligent lock device management system that enables direct control of the system or control of the controller. It connects the exit button directly to the Lock system to reduce the unnecessary steps by performing the door opening function. Reduce costs by streamlining wiring by increasing efficiency and reducing steps. It is a lock management system that reduces the frequency of communication signal failures and provides a power saving effect of the system through TCP / IP (PoE) communication as a system suitable for security facilities in power plants and public buildings.

  • Monitoring & Report

    • Appliance Installation Information
    • Door state
    • Service connection status (Controller, Network (PoE))
  • Control

    • Control of device operation (Controller ↔ Network (PoE))
    • Forced door OPEN / CLOSE via Network (PoE)

Magnetic Lock (EACA-L100 / L180 / L100S)

It is a magnetic lock device that controls the locking and unlocking of the door by the electric magnetic action of the lock body and the armature plate.
It is used for the doors of fire doors, glass doors and wooden doors which are opened and closed in one direction. EACA-L100S is a locking device that can operate independently without ACU controlling.

Product Characteristics

  • Tensile strength: 320, 280KG
  • Door Status Monitoring (Magnet Switch)
    • You can monitor door open and close status using contact and TCP / IP communication.
  • EACA-L100S
    • Provides various functions through TCP / IP (PoE) communication for power, monitoring and control in case of controller failure.

Product Specifications

모델명 EACA-L100 EACA-L180 EACA-L100S
Monitoring Program EACA-L100- EACA-L180- EACA-L100SDoor Status, Power Condition, Door Control
Power EACA-L10012V DC 500mA EACA-L18012V DC 500mA EACA-L100S12V DC 500mA, PoE
Tensile Force EACA-L100320kg (705lbs) EACA-L180280kg (617lbs) EACA-L100S320kg (705lbs)
Weight EACA-L1002.5kgs EACA-L1801.0kgs EACA-L100S-
Lock status detection switch EACA-L100COM, NO, NC EACA-L180COM, NO, NC EACA-L100SCOM, NO, NC, TCP/IP
Operating temperature EACA-L100-10~50℃ EACA-L180-40~55℃ EACA-L100S-20~50℃
Humidity EACA-L1000~95% (non-condensing) EACA-L1800~90% (non-condensing) EACA-L100S20~80%(non-condensing)
Size EACA-L100240(l) x 50(w) x 28(h) mm EACA-L180170(l) x 34(w) x 20.5(h) mm EACA-L100S300(l) x 66(w) x 30(h) mm
Status LED EACA-L100Red: Open
Green: Closed
EACA-L180Red: Open
Green: Closed
EACA-L100SRed: Open
Green: Closed
Ethernet : Communication Status

Schematic Diagram